Heat Treatment of Metals ›› 2021, Vol. 46 ›› Issue (10): 199-203.DOI: 10.13251/j.issn.0254-6051.2021.10.035

• PROCESS RESEARCH • Previous Articles     Next Articles

Effect of post-weld tempering temperature on microstructure and room temperature mechanical properties of G115 steel deposited metal

Qi Xiangqian   

  1. Engineering Technology Department, Tianjin Maritime College, Tianjin 300372, China
  • Received:2021-06-04 Online:2021-10-25 Published:2021-12-08

Abstract: G115 steel filler rod was welded on a steel test plate, and then the post-weld tempering for the plate was carried out at 760, 780, 800 and 820 ℃, respectively. The mechanical properties and microstructure of the weld-deposited steel plate under different tempering temperatures were analyzed. The results show that the best tempering temperature of the G115 steel deposited on the plate is 800 ℃. With the increases of the tempering temperature, the precipitation phase M23C6 has a growing-up trend. The impact fracture of the steel plate tempered at 760-820 ℃ is characterized by dimple fracture and quasi-cleavage fracture. Spherical second phase particles are observed in the dimples which formed during the deoxidation reaction in welding metallurgy process.

Key words: G115 steel, deposited metal, tempering, martensite, mechanical properties, microstructure

CLC Number: