Analysis of cracking cause of acid gas post-cooler head

Liu Min1, Lu Meipeng1, Liu Jiachen2, Gu Baolan2, Guo Jing2, Sun Yuejun1, Song Ming2   

  1. 1. College of Materials Science and Engineering, Liaoning Technical University, Fuxin Liaoning 123000, China;
    2. China Special Equipment Inspection and Research Institute, Beijing 100020, China
  • Received:2023-04-25 Revised:2023-07-03 Online:2023-08-25 Published:2023-10-10

Abstract: Bulges and cracks appeared in the inner wall of floating head of acid gas post-cooler in a natural gas purification plant. The causes of bulges and cracks were analyzed by means of macroscopic examination, chemical composition analysis, hardness test, metallographic examination, energy spectrum analysis, fracture analysis and EBSD test. The results show that the bulge and cracking of the inner wall of the head are hydrogen bulge (HB) and hydrogen-induced cracking (HIC). Since the microstructure of the head material (20g steel) is banded ferrite+pearlite along the rolling direction, with bainite and more MnS inclusions appearing at the position of 1/2 plate thickness caused by element segregation, and the service environment of the head contains wet H2S medium which generates hydrogen after electrochemical reaction with the steel, then the hydrogen accumulates at the defects of 1/2 plate thickness, leading to bulge and cracking of the inner wall of the head.

Key words: 20g steel, wet H2S environment, microstructure, MnS inclusion, hydrogen-induced cracking, bulge