Heat Treatment of Metals ›› 2022, Vol. 47 ›› Issue (7): 286-288.DOI: 10.13251/j.issn.0254-6051.2022.07.050

• TEST AND ANALYSIS • Previous Articles    

Fracture cause analysis of QBe2 beryllium bronze connector

Wei Caili1,2, Zhang Shenjie1,2, Du Gangfeng1,2   

  1. 1. Manufacturing Engineering Center, First Tractor Company Limited, Luoyang Henan 471004, China;
    2. Luoyang Key Laboratory of Mechanical Product Failure Analysis, Luoyang Henan 471004, China
  • Received:2022-03-17 Revised:2022-05-20 Online:2022-07-25 Published:2022-08-12

Abstract: A batch of connector made of QBe2 fractured in the course of service was fratured. Reason for fracture was analyzed by the methods such as microscopic morphology observation, chemical composition analysis, microstructure observation and hardness test; and contral mensuren was proposed. The results show that overheating of the connector caused in thermocouples fail lead to coarse grain in solution and aging treatment. The strength of the grain boundary becomes lower than the matrix, and lead to the fracture of connector when it is subjected to external force. Therefore, it is recommended to regularly monitor and maintain the thermocouple to ensure the normal operation of the equipment.

Key words: beryllium bronze, overheating, fracture